NO CALIBRATION REQUIRED – EVER.

NO CALIBRATION

MARQMETRIX RAMAN FACTORY CALIBRATION

Every MarqMetrix All-In-One Process Raman System leaves our facility factory calibrated, ensuring continuous and precise process Raman analysis. Since March 2019, we have been conducting a calibration study on an All-In-One spectrometer to demonstrate the stability and performance of our Raman instruments without recalibration.

MARQMETRIX CALIBRATION STUDY AT A GLANCE

MARQMETRIX CALIBRATION STUDY AT A GLANCE

MarqMetrix All-In-One calibration study began in March 2019

MARQMETRIX CALIBRATION STUDY AT A GLANCE

Nine Raman peak positions of cyclohexane were monitored per ASTM standard

MARQMETRIX CALIBRATION STUDY AT A GLANCE

10 spectra were collected per week

MARQMETRIX CALIBRATION STUDY AT A GLANCE

Currently, a total of 840 spectra (and counting) have been collected over this period

MARQMETRIX CALIBRATION STUDY AT A GLANCE

Wavelength calibration has been extremely stable for more than 1.5 years
±0.1cm-1 (±1.5%) accuracy –  5x lower than reported ASTM reference accuracy

RESULTS

The MarqMetrix All-In-One spectrometer has been stable and accurate within ±0.1cm-1 (±1.5%) 5x lower than reported ASTM reference accuracy without recalibration as of DATE OF UPDATE. MarqMetrix will continue to update this page with calibration study results.

RAMAN SPECTRAL DATA 

marqmetrix raman analyzer
  • 840 Raman spectra overlay over an 84-week study to illustrate stability in calibration

ACCURACY OVER 84-WEEKS

marqmetrix raman analyzer
  • Calibration accuracy is ±0.1cm-1, 5x lower than ASTM reference accuracy

HOW ARE WE MEASURING HARDWARE STABILITY?

Calibration stability and reproducibility between Raman instruments allow for the use of global models. This capability greatly reduces both the cost of ownership and implementation cost for additional Raman systems. At MarqMetrix, our mission is to make Raman accessible to all, and calibration stability plays an integral role by eliminating the need for costly scientists to assure and maintain the device.

The MarqMetrix All-In-One Process Raman system has proven to be stable within plus or minus 1.5% for more than 1.5 years with zero recalibration. The only time this machine was calibrated was when it was built in the MarqMetrix production facility.

WHY IS CALIBRATION STABILITY IMPORTANT?

MarqMetrix has been conducting a long-term calibration study on a single All-In-One device since March 2019. Nine Raman peak positions of cyclohexane are being monitored throughout this experiment to prove long-term wavelength calibration stability. MarqMetrix is using the American Society for Testing and Materials (ASTM) Calibration Standard as a comparison.

ASTM standard

ALL-IN-ONE

ALL-IN-ONE FACTORY CALIBRATION BENEFITS

ZERO DOWNTIME

Raman systems that require recalibration cannot continue to take measurements while they are being recalibrated. Precious time and data is wasted while recalibrating traditional Raman devices. With a MarqMetrix All-In-One Process Raman System, you never have to waste time recalibrating your Raman equipment. Our systems are designed to run continuously. As this calibration study proves, they can operate for more than 1.5 years (and running) without needing calibration or maintenance.

LOWER COSTS

Traditional Raman systems often necessitate expert personnel, extensive training, or other costly equipment to keep them running smoothly. The MarqMetrix All-In-One Process Raman system doesn’t require weekly, monthly or even yearly recalibration. With the All-In-One, your scientists can focus on science not hardware maintenance. MarqMetrix products allow you focus resources on your business, not device maintenance.